- THERE SHOULD BE AT LEAST 1 SQ. FT. OF UNRESTRICTED ATTIC
VENTILATION FOR EVERY 150 SQ. FT. OF CEILING AREA IF THERE IS NO
VAPOR BARRIER.
- THERE SHOULD BE AT LEAST 1 SQ. FT. OF NET FREE VENTILATION AREA (NFVA)
FOR EVERY 300 SQ. FT. OF CEILING AREA IF THERE IS A VAPOR BARRIER.
BRENDA AT LOMANCO (800) 643-5596 CONFIRMS THE FOLLOWING:
1. WITH A STATIC SYSTEM (EXAMPLE - SOFFIT / CORNICE VENTS AND
CONTINUOUS RIDGE VENT) THE NFVA SHOULD BE DIVIDED EQUALLY BETWEEN
MAKE-UP AND EXHAUST AIR.
2. 80 SQ. INCHES OF NFVA / 100 CFM OF POWER VENTILATION IS A
GENEROUS THUMB RULE FOR MAKE-UP AIR PROVISION WITH A POWER EXHAUST
UNIT. ALL POWER VENTILATOR MANUFACTURER’S SPECIFY HOW MUCH NFVA IS
REQUIRED WITH THEIR UNITS AND THIS DEPENDS ON THE SIZE OF THE UNIT.
SHINGLE ROOF SYSTEMS - MUST HAVE VENTILATION BELOW DECKING TO
VENT AND CONTROL MOISTURE IN ATTIC & TO INSURE MANUFACTURERS
WARRANTY ON SHINGLES WILL NOT BE VOIDED.
CRAWLSPACE VENTILATION CONCERNS - THIS LINKS LEADS TO A GREAT
ARTICLE ABOUT CRAWLSPACE VENTILATION CONCERNS. CRAWLSPACE
MYTHS
DRYER VENT - BROTHER KEVIN CHECKED IN TO SAY HIS RESEARCH
REVEALED DRYERBOX.COM HAD BOTH GOOD INFORMATION AND PROMISING
PRODUCTS. KEVIN'S IN ATLANTA AND IS HAVING SHUMATE MECHANICAL, (678)
584-0880, DO THE INSTALLATION FOR HIM. POINT BEING, WAY TOO
MANY DRYER VENTS AREN'T INSTALLED WITH SOLID METAL DUCT OR WITH THE PROPER
LENGTH / CONFIGURATION IN WHICH CASE YOU GOT A SERIOUS FIRE HAZARD Y'ALL.