PACKAGE SHOULD INDICATE YOU HAVE AN Al/Cu CONNECTOR -
IDEAL INDUSTRIES 1-800-435-0705 MANUFACTURES THE
"TWISTER" WHICH HAS A DIELECTRIC PASTE INSIDE THAT STOPS
CORROSION DUE TO THE TWO DISSIMILAR METALS.
CONNECTING COPPER WIRING - USE WIRE
NUTS OR FOOLPROOF P-NUT (12- TO 18-GUAGE WIRE). P-NUTS
MANUFACTURED BY IMPROVEMENTS - 1-800-642-2112.
ADDING A GROUNDING WIRE TO ELECTRICAL SYSTEM
-
IS DIFFICULT AND BEST DONE BY A LICENSED ELECTRICIAN. GOOD
ALTERNATIVE IS TO INSTALL A GFCI (GROUND FAULT CIRCUIT INTERRUPTER)
RECEPTACLE. RECEPTACLE IS NOT GROUNDED BUT YOU’RE PROTECTED FROM
ELECTRICAL SHOCKS AND YOU CAN USE 3-PRONG PLUGS. IF YOU INSTALL GFCI
AT FIRST FIXTURE COMING FROM PANEL ON A CIRCUIT, THE REST OF THE
CIRCUIT IS PROTECTED AND 3-PRONG RECEPTACLES CAN BE INSTALLED. MARK
ALL RECEPTACLES ON SUCH A CIRCUIT WITH STICKER AVAILABLE FROM
ELECTRICAL SUPPLY HOUSES MARKED "GFCI PROTECTED".
TROUBLESHOOTING ELECTRICAL OUTLETS
CHECK SAFETY OF ELECTRICAL OUTLETS WITH A RECEPTACLE TESTER /
CIRCUIT ANALYZER. COST ABOUT $10.00. JUST PLUG TESTER IN AND MATCH
LIGHT PATTERN TO PATTERNS SHOWN ON TESTER.
A.W. SPERRY (800) 645-5398. CAUTION - THIS UNIT DOES NOT INDICATE
REVERSED GROUND & NEUTRAL.
TWO MOST COMMON PROBLEMS ARE REVERSED
POLARITY AND AN OPEN GROUND.
REVERSED POLARITY -
FIXTURES AND APPLIANCES WILL OPERATE
PROPERLY WITH THIS CONDITION, BUT A PERSON COULD BE SERIOUSLY INJURED
IF A SHORT OCCURS. EXAMPLE, AN OLDER REFRIGERATOR HAS THE GROUND
BONDED TO THE NEUTRAL CIRCUIT. IF THE POLARITY IS REVERSED SO THE
NEUTRAL IS "HOT", THE ENTIRE REFRIGERATOR IS MADE
"HOT". WASHERS AND STOVES HAVE THE SAME CIRCUITRY, I.E., THE
GROUND IS BONDED TO THE NEUTRAL, BUT IN BOTH CASES THE "HOT"
IS 220 VOLTS VS. 120 VOLTS AND THE APPLIANCE MAY IMPLODE!!!!
IF THE CIRCUIT ANALYZER INDICATES REVERSED POLARITY IN AN OUTLET,
KILL POWER AT THE PANEL, THEN:
- REMOVE THE COVER PLATE.
- PULL THE OUTLET OUT OF THE BOX.
- INSURE THE BLACK (HOT) WIRE IS ATTACHED TO SCREW OF THE SHORTER
SLOT.
- INSURE THE WHITE (NEUTRAL) WIRE IS ATTACHED TO THE LONGER SLOT
SCREW.
- REINSTALL AND RECHECK THE OUTLET. CAUTION - IF THE POLARITY
PROBLEM PERSISTS, CONTACT A LICENSED ELECTRICIAN.
OPEN GROUND - FIXTURES AND
APPLIANCES WILL OPERATE PROPERLY WITH THIS CONDITION, BUT A PERSON COULD
BE SERIOUSLY INJURED IF A SHORT TO GROUND OCCURS.
IF THE CIRCUIT ANALYZER INDICATES REVERSED POLARITY IN AN OUTLET,
KILL POWER AT THE PANEL, THEN:
- REMOVE THE COVER PLATE.
- PULL THE OUTLET OUT OF THE BOX.
- CHECK THAT THE GROUND "PIGTAIL" (BARE OR GREEN
SHEATHED COPPER WIRE) IS SECURELY ATTACHED TO THE RECEPTACLE’S
GREEN GROUND SCREW AND TO THE GROUND CIRCUIT WIRES IN THE PLASTIC
WIRE CONNECTOR.
- REINSTALL AND RECHECK THE OUTLET. CAUTION - IF THE OPEN GROUND
PROBLEM PERSISTS, CONTACT A LICENSED ELECTRICIAN.
OVERCURRENT PROTECTION DEVICES - OHMS LAW :
WATTS / VOLTS (120) = AMPS
MOST HOUSE CURRENT IS ON A 15 AMP CIRCUIT (14-GAUGE WIRE) OR A
20 AMP CIRCUIT (12-GAUGE WIRE). SINGLE APPLIANCE CIRCUITS LIKE A
DRYER, ELECTRIC STOVE, OR AIR CONDITIONING UNIT HAVE LARGER WIRES
SUPPLYING THEIR POWER AND ARE RATED FOR 30 OR 50 AMPS.
NEC REQUIRES KITCHENS TO HAVE AT LEAST TWO 20 AMP CIRCUITS TO HANDLE
THE APPLIANCES THERE. 1. ELECTRIC RANGE / 2. DISHWASHER / 3.
BUILT-IN MICROWAVE MUST HAVE DEDICATED CIRCUITS TO AVOID OVERLOADS DUE
TO THE CURRENT THESE APPLIANCES DRAW.
OVERCURRENT PROTECTION DEVICES ARE HEAT -SENSITIVE (FUSES)
OR CURRENT-SENSITIVE (SOME CIRCUIT
BREAKERS)
OR HEAT / CURRENT-SENSITIVE (SOME
CIRCUIT BREAKERS)
CAUTION: IF AN OVERLOAD IS SLIGHT (100% - 150%) A CIRCUIT BREAKER MAY
NOT TRIP FOR A MINUTE OR TWO. IF IT TRIPS IMMEDIATELY, THERE’S A
SERIOUS OVERLOAD CONDITION.
NOTE: FUSES ARE NOT INFERIOR TO CIRCUIT BREAKERS - THEY’RE ACTUALLY
SAFER IN TERMS OF THE INCONVENIENCE OF A CIRCUIT THAT IS CONTINUALLY
OVERLOADED AND NEEDS ATTENTION.
CAUTION: NEVER PUT A 20 AMP FUSE ON A 15 AMP CIRCUIT. THE WIRING
RATED FOR 15 AMPS WILL BE OVERLOADED AND COULD OVERHEAT AND CAUSE A
FIRE.
COMMON AMPERAGE DRAW:
| WINDOW AIR CONDITIONER --------- 8 -
16 |
CLOTHES WASHER ---------------- 10 |
| TABLE SAW
------------------------------- 13 - 15 |
PORTABLE HEATER --------------- 10 |
| AIR COMPRESSOR
----------------------- 10 - 15 |
TOASTER -----------------------------
7 - 10 |
| REFRIGERATOR
-------------------------- 6 - 15 |
COFFEE MAKER -------------------- 6 -
10 |
| TOASTER OVEN
-------------------------- 12 |
GARBAGE DISPOSER ------------- 5 - 10 |
| MICROWAVE (COUNTERTOP) -------- 6 -
12 |
CLOTHES IRON --------------------- 9 |
| DISHWASHER (PORTABLE)------------11 |
DEHUMIDIFIER --------------------- 7 |
| HAIR DRYER
------------------------------ 10 |
FREEZER (NEWER MODEL) ----- 5 |
CENTRAL SURGE STOPPER - SIEMENS’
CIRCUIT BREAKER / SURGE ARRESTOR WIRES INTO A HOME CIRCUIT LIKE ANY
OTHER CIRCUIT BREAKER AND PROTECTS EVERY ELECTRONIC FIXTURE ON THAT
CIRCUIT FROM VOLTAGE SURGES. SHOULD BE INSTALLED BY A LICENSED
ELECTRICIAN. 1-404-751-2000.
COMMON OVERLOAD CONDITIONS:
- TOO MANY APPLIANCES ON A CIRCUIT.
- CONTINUALLY RUNNING WINDOW AIR CONDITIONERS ON A MARGINAL ADEQUATE
CIRCUIT THAT GRADUALLY HEAT UP WIRING.
- STARTER MOTORS IN POWER TOOLS THAT DRAW MUCH MORE CURRENT THAN THE
TOOL’S RATING.
- POWER TOOL MOTOR BOGS DOWN UNDER AN EXTREME LOAD.
HOW TO PREVENT OVERLOADS:
- PLUG THE APPLIANCE THAT’S CAUSING THE PROBLEM ON ANOTHER
CIRCUIT. CAUTION: THE NEC DOES NOT ALLOW EXTENSION CORDS UNLESS
THE USE IS TEMPORARY, LIKE FOR A POWER TOOL.
- RUN ANOTHER CIRCUIT FROM THE PANEL & INSTALL A RECEPTACLE TO
SERVICE THE APPLIANCE (S) DRAWING THE MOST POWER.
- LABEL YOUR PANEL SO YOU KNOW WHAT IS ON EACH CIRCUIT AND
CAN SHIFT APPLIANCES AROUND TO BALANCE THE LOAD.
- FLIP A BREAKER OFF OR LOOSEN A FUSE.
- GO THROUGH THE HOUSE WITH A UTILITY LIGHT OR RADIO, PLUGGING
IT IN EACH RECEPTACLE & TURNING ON LIGHT SWITCHES AS YOU GO.
- IF THE LIGHT / RADIO DOESN’T COME ON, OR THE SWITCH DOESN’T
WORK, YOU KNOW THE SWITCH OR RECEPTACLE IS ON THE DEAD CIRCUIT.
- LABEL YOUR PANEL AND PUT THE APPROPRIATE INFORMATION ON A
SKETCH OF THE FLOOR PLAN OF YOUR HOME.
- SHIFT APPLIANCES AROUND TO BALANCE THE LOAD ON EACH CIRCUIT.
NOTE: IF THE PANEL ISN’T LABELED AND YOU NEED TO FIND WHICH FUSE
/ CIRCUIT BREAKER SHUTS OFF AN OUTLET, PLUG IN A DRILL OR JIGSAW
WITHOUT THE BLADE, PRESS THE HOLD BUTTON THAT KEEPS IT RUNNING, THEN
GO TO THE PANEL AND KILL CIRCUITS UNTIL THE NOISE STOPS.
ELECTRICAL HAZARDS:
- SCREW-IN RECEPTACLES - LIGHT SOCKETS ARE USUALLY RATED FOR
6 AMPS, A LOT LESS THAN A REGULAR PLUG-IN RECEPTACLE’S 15 AMP
CAPACITY. THE POINT IS, THE CIRCUIT THE LIGHT FIXTURE IS ON CAN
HANDLE AT LEAST A 15 AMP CAPACITY BEFORE THE SAFETY LIMIT IS
EXCEEDED & THE FUSE / BREAKER CUT THE CURRENT FLOW. IF A 10 AMP
GIZMO IS PLUGGED INTO THE LIGHT SOCKET RECEPTACLE, OVERHEATING WILL
MELT WIRE INSULATION & SET UP IDEAL CONDITIONS FOR A FIRE.
- TAPS / "OCTOPUS PLUGS" / MULTIPLE PLUG ADAPTERS - THESE
LITTLE DEVICES FROM HELL MAKE IT POSSIBLE TO PLUG SEVERAL ITEMS INTO
A SINGLE RECEPTACLE. FIRST, THE CIRCUIT CAPACITY CAN EASILY
BE OVERLOADED WHICH WILL RESULT IN THE FUSE / BREAKER CUTTING OFF
POWER. WHEN THIS HAPPENS REPEATEDLY, THE CIRCUIT CAN BE DAMAGED. SECOND,
"OCTOPUS PLUGS" WEAR OUT AND POOR CONNECTIONS RESULT. WORN
CONNECTIONS CAUSE HEAT. EXCESSIVE HEAT IN AN ELECTRICAL CIRCUIT
TRAUMATIZES INSULATION. DAMAGED INSULATION RESULTS IN FIRES.
- ADAPTER PLUGS - THESE INSTRUMENTS OF INIQUITY ALLOW A
THREE-PRONG PLUG TO GET POWER FROM A TWO-PRONG RECEPTACLE WHICH
BYPASSES THE GROUNDING FEATURE THAT PROTECTS YOU FROM A POTENTIALLY
FATAL SHOCK. DON’T TRY TO GROUND THE TWO-PRONG RECEPTACLE. INSTALL
A GFCI RECEPTACLE IN PLACE OF THE TWO-PRONG RECEPTACLE.
- RECEPTACLES LOOSE / MOUNTED TOO DEEP - WITH NON-FLAMMABLE
WALL, EX. DRYWALL, PLASTER, THE EDGE OF THE RECEPTACLE MUST NOT BE
MORE THAN 1/4" BEHIND WALL SURFACE. WITH FLAMMABLE WALL,
EX. WOOD, HARDBOARD, THE EDGE OF THE RECEPTACLE MUST BE FLUSH WITH
THE WALL SURFACE. RECEPTACLE NO MORE THAN 1/4" OUT OF
ADJUSTMENT SPACE OUT WITH NO. 6 STEEL WASHERS. RECEPTACLE MORE
THAN 1/4" OUT OF ADJUSTMENT, INSTALL AN EXTENSION RING.